Railings are permitted up to 48 inches above the midway point between the highest and lowest points of the roof.
Philadelphia roof deck access structures.
The area below the deck shall not be enclosed.
Access to the deck is via an exterior balcony and stair resulting in no loss of valuable space inside.
Maximum size of deck.
Green roofs must be designed to allow for safe access and working conditions for green roof inspection and maintenance personnel.
Roof gardens see section b 1504 of title 4 temporary structures see b 102 of title 4 storage of refuse see b 424 of title 4.
2 except in the rm 2 rm 3 rm 4 rmx 3 cmx 3 cmx 4 cmx 5 and irmx districts the roof deck access structure may not exceed 90 125 sq.
Structure to be fully sprinklered per nfpa 13r min.
For use as multi family household living three 3 dwelling units.
Roof deck access structures known as pilot houses may extend above the maximum height allowed for the building see below if they only serve to enclose the access stairs and do not exceed 10 feet in height.
This design demonstrates how the roof of a small philadelphia rowhouse can be inhabited and the entire house dramatically expanded and transformed offering contact with the sun the sky the wind and the stars and welcome relief from the.
For posternack construction typically takes about a month with more time added if the deck requires a pilot house a shed like structure with an interior staircase.
C roof deck access structures.
Deck shall not be located in the front or side yards.
For philadelphia roof decks are for all seasons getting the proper permits from the city takes about 90 days assuming that everything goes smoothly.
For the erection of an attached structure with a roof deck accessed by a pilot house to enclose access stairs only and a deck at the second floor rear size and location as shown on plans.
City of philadelphia 2 1 the roof deck access structure may only serve to enclose the access stairs elevators or other means of access.
An example of a green roof in philadelphia.
You ll want to make sure all existing or planned structures are in line with the requirements of the philadelphia code.
Roof decks are prohibited on accessory structures.
In area however roof deck access structures that also.
Deck shall not have a roof walls or stairs leading to grade.
In height and may only serve to enclose the access stairs.
This access must be a permanent feature of the building such as a.
A minimum distance of 3 0 shall be maintained from the deck to the rear property line or to the common driveway.
Roof decks are subject to compliance with 14 604 5 a through 14 604 5 c below.
Such structures may fit into the following code categories.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.