The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Occupied roof ibc 2015.
Or os the general opinion that an occupied roof is allowed above the upper story and is something different since it would be unenclosed and open to the sky.
A question that is commonly asked on projects is how to classify the occupancy of occupied roof decks.
Where one exit or exit access stairway or ramp providing access to exits at other stories is permitted to serve individual stories mixed occupancies shall be permitted to be served by single exits provided each individual occupancy complies with the applicable requirements of table 1006 3 2 1 or 1006 3 2 2 for that occupancy.
Under the 2015 ibc and prior editions no guidance is given with respect to this issue.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Note that new section 1006 3 egress from stories or occupied roofs has been added to the 2015 ibc.
Roof pressure coefficient for each applicable roof zone determined from chapter 30 of asce 7.
For the occupant load reduction to 25 max see ibc 1004 1 2 exception.
I did a rooftop deck in city of la a few years ago.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
If the relationship between an occupied roof and table 504 4 is not clear is a code.
Where applicable cumulative occupant loads from adjacent.
Does the roof deck contribute to the building area.
Does the height and area table ibc table 503 apply to the outdoor area.
The means of egress system serving any story or occupied roof shall be provided with the number of exits or access to exits based on the aggregate.
International building code 2015 ibc 2015.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Ibc 2015 section 1006 3 added language which specifically recognizes that occupied roofs exist and stipulates egress requirements associated with them.
An assembly occupancy on an occupied roof that exceeds an occupant load of 100 for group a 2 occupancy and 300 for all other group a occupancies requires all floors between the occupied roof and level of exit discharge to be equipped with an automatic fire sprinkler system except for open parking garages built with type i or type ii construction.
Check table 1006 3 for maximum travel distance 75 for b occupancy i believe.
1006 3 egress from stories or occupied roofs.